IRT-5000 Microscope

irt-5000-microscope
JASCO has developed the IRT-5000, an innovative FT-IR microscope accessory with advanced functionality which drastically improves the ability to obtain micro-spectroscopic data.

Features

Micro FT-IR has generally been reserved for measuring specified samples such as small contaminants on polymer films or micro samples transferred to infrared transparent windows. Today, JASCO’ s innovative FT-IR Microscopes, the IRT-5000 Series, provide new functions that dramatically improve infrared micro-spectroscopy analyses. These microscope systems can be easily interfaced with the FT/IR-4000 or FT/IR-6000 series spectrometers, offering the most advanced microscopy and imaging systems available in the market. Coupling JASCO’ s proven technology for infrared spectroscopy, accumulated over 50 years, with the most advanced optical design, the IRT-5000 Series offer the best solution for even the most challenging sample analyses.

System Description

The IRT-5000 FT-IR Microscope employs a mid-band MCT detector as standard, while up to two detectors can be installed simultaneously to expand the spectral range of the microscope. The standard "IQ Mapping" function allows multi-point, line, area and ATR mapping experiments without moving the sample stage, in addition to single-point measurements. An optional automatic X-Y-Z sample stage enables auto-focus and mapping analysis of a large sample area. With the addition of a linear array detector, the microscope can be easily upgraded for IR imaging in the field.

System Features

  • IQ Mapping without moving sample stage
  • Dual detector capability and user replaceable detectors
  • Multiple objective capability and automatic switching
  • Exceptional visual observation quality
  • IQ Monitoring for simultaneous observation of the spectrum and sample image
  • Spectrum preview to check conditions before measurement
  • Data storage linked with sample image and aperture information
 

IRT-5100: FT-IR Microscope

Manual sample storage DLATGS detector

The IRT-5100 is a general purpose FT-IR microscope employing a standard DLATGS detector with no need for liquid nitrogen cooling. The IRT-5100 can also integrate an additional detector which can be simultaneously installed. An optional automatic XYZ sample storage provides auto-focus and mapping analysis capabilities.

  • Dual detector capability
  • Variety of measurement modes (Transmission, reflection, ATR, Grazing Angle Reflection)
  • Multiple objective capabilities
  • Optional automatic sample storage
 

IRT-5200: FT-IR Microscope

Manual sample storage Mid-band MCT detector

The IRT-5200 FT-IR microscope utilizes a standard mid-band MCT detector, while up to two detectors can be simultaneously installed as an option. The standard "IQ Mapping" function allows multi-point, line, area and ATR mapping experiments without moving the sample storage, in addition to single-point measurements. An optional automatic XYZ sample stage enables auto-focus and mapping analysis of larger sample areas.

  • IQ Mapping
  • Dual detector capability
  • Variety of measurement modes (Transmission, reflection, ATR, Grazing Angle Reflection)
  • Multiple objective capabilities
  • Field upgrade to IR Imaging System using a linear array detector
 

User-friendly Micro Analysis Measurement Program

A full-featured software package, Spectra Manager™ II provides automatic functions and simplified operational procedures to minimize manual operations. Measurement conditions, microscope sample monitoring/control operations and measurement results can be reviewed in a single screen. The dedicated microscope interface provides various types of measurements such as single and multiple points, mapping, and linear array measurements using a single mouse-click for mode selection. Real time monitoring of the spectrum and a calculated chemical image can be specified during the mapping measurement.

Innovative ATR Mapping

The "Clear-View" ATR objectives enable a simultaneous sample view even during ATR data collection after the ATR crystal element contacts the sample. The IQ Mapping function enables automated multi-point mapping, line mapping, grid mapping and IR Imaging analyses of a microscopic area with a manual sample stage and a single element detector.

IQ Mapping coupled with a "Clear-View" ATR objective allows ATR mapping and ATR Imaging of any sample in contact with the ATR objective without moving the sample stage or ATR objective, while observing the entire area of the sample that is in contact with the crystal element. This function provides high-speed and cross-contaminant free measurements of a small sampling area.

Full-vacuum System

For FT-IR measurement, absorption peaks due to atmospheric water vapor and CO2 can make it difficult to obtain high quality sample spectra. The most effective solution to this problem is the measurement of samples in vacuum. As a factory option, a vacuum type FT-IR microscope system can be provided.

 

FTIR Microscope Specifications

Principle FT-IR microscope with cassegrain optical system
Measurement Method Transmittance / Reflectance measurement
Standard Detector IRT-5100: DLATGS detector (7800-400 cm -1)
IRT-5200 & IRT-7100: Single mid-band MCT (7800-600 cm -1)
IRT-7200: Linear array MCT (7000-650 cm -1 x 16 element)
Single mid-band MCT (7800-600 cm)-1
Detector exchange Dual detector capability (software controlled), user exchangeable single element detectors are available as an option.
• Optional Detectors Single element detector (IRT-5100):
- Narrow-band: MCT (5000-750 cm-1)
- Mid-band: MCT (7800-600 cm-1)
- Wide-band: MCT (7800-450 cm-1)
- InSb: (15000-1850 cm-1)
- InGaAs detector: (12000-4000 cm-1)

Single element detector (IRT-5200, IRT-7100, & IRT-7200):
- Narrow-band: MCT (5000-750 cm-1)
- Wide-band: MCT (7800-450 cm-1)
- DLATGS: (7800-400 cm-1)
- InSb: (15000-1850 cm-1)
- InGaAs detector: (12000-4000 cm-1)

Linear array detector (IRT-5200, IRT-7100):
- MCT (7000-650 cm-1), 1 x 16 element
- MCT (7000-650 cm-1), 2 x 16 element
- InSb (10000-1900 cm-1), 1 x 16 element
- InGaAs (10000-5000 cm-1) , 1 x 16 element

Linear array detector (IRT-7200):
- MCT (7000-650 cm-1), 2 x 16 element
- InSb (10000-1900 cm-1), 1 x 16 element
- InGaAs (10000-5000 cm-1) , 1 x 16 element

S/N Ratio Single element detector (IRT-5100):
- 1000:1 (Aperture size 300 μm2, resolution 4 cm-1, 1 min. acquisition, near 2200 cm-1, p-p)

Single element detector (IRT-5200, IRT-7100, & IRT-7200):
- 8000:1 (Aperture size 100 μm2, resolution 4 cm-1, 1 min. acquisition, near 2200 cm-1, p-p)

Linear array detector (IRT-7200):
- 1500:1 (Aperture size 12.5 μm2, resolution 16 cm-1, 1 min. acquisition, near 2200 cm-1, p-p)

Microscope objectives IRT-5100, IRT-5200, & IRT-7100:
- Cassegrain: 16 x 32 x or 10 x
- Automatic objective recognition function (standard)
- Up to four objectives can be selected by the software.

IRT-7200:
- Cassegrain: 16 x 32 x as standard, 10 x as option
- Automatic objective recognition function (standard)
- Up to four objectives can be selected by the software.

Condenser mirror IRT-5100, IRT-5200, & IRT-7100:
- Cassegrain: 16 x 32 or 10 x (manual exchange)
- Automatic condenser mirror recognition function (standard)

IRT-7200:
- Cassegrain: 16 x, 32 x as standard (manual exchange), 10 x as option

Condenser mirror compensation Standard auto-compensation function
Aperture PC-controlled vertical horizontal adjustment and angle of rotation
Sample Storage Standard (IRT-5100 & IRT-5200):
- Manual stage with fine adjustment (Movable distance: X: 70, Y: 50, Z: 20 mm)

Standard (IRT-7100 & IRT-7200):
- Auto XYZ stage with auto-focus function (Movable distance: X: 100, Y: 75, Z: 25 mm, 1 μm step)

Option (IRT-5100 & IRT-5200):
- Auto XYZ stage with auto-focus function (Movable distance X: 100, Y: 75, Z: 25 MM, 1 μm step Joystick for auto XYZ stage control)

Option (IRT-7100 & IRT-7200):
- Joystick for auto XYZ stage control

Auto focus Option (IRT-5100 & IRT-5200)
Standard (IRT-7100 & IRT-7200)
IQ Mapping Standard (IRT-7100 & IRT-7200)
Sample Observation High-resolution, 3 Megapixel CMOS camera with a 3X optional zoom function (standard)
IQ Monitor (simultaneous sample measurement and observation) and auto illumination function (standard)
5.7 inch integrated color LCD display (option), Binocular (option)
• Observation Options Visible polarization observation, Differential interference contrast observation, Fluorescence observation
Refractive objectives: 10×, 20×
Microscope Objectives Cassegrain 16× - standard; 10×, 32× - optional
Automatic objective recognition function is standard.
Up to four objectives can be selected by the software.
• ATR Measurement (option) "Clear-View" ATR objective (ATR-5000-SS/SD/SG)*1,
conventional ATR objective (ATR-5000-D/Z/G)*1,
Stage-mounted micro ATR using transmittance light path (ATR-5000-TPZ)
• Grazing Angle Measurement (option) Cassegrain grazing angle objective (RAS-5000)*2
Purge Sample area purge case is optional as an option.
Integrated Control Panel Transmittance/Reflection switching with indicator; detector indicator; objective selection/indicator; open/close and rotation of aperture; auto-compensation of condenser mirror; visible illumination adjustment
Dimension IRT-5100 & IRT-5200:
587 (H) × 302 (W) × 695 (D) mm, 54 kg

IRT-7100 & IRT-7200:
613 (H) × 302 (W) × 695 (D) mm, 56 kg

Power Consumption IRT-5100 & IRT-5200:
AC 100-240 V, 50/60 Hz, max. 60 VA

IRT-7100 & IRT-7200:
AC 100-240 V, 50/60 Hz, max. 75 VA

*1 Pressure sensor (PRS-M-5000, PRS-A-5000) is required.

*2 Infrared polarizer (PL-IR-5000, PL-IR-7000) is required.

Details

Standard Composition

Standard Set-up

Description Quantity
IRT-5000 Microscope
including
- Objective cassegrain (16×, 32×, or 10×)
- Condenser cassegrain (16×, 32×, or 10×)
- MCT detector
- CMOS camera
-Manual stage
1 set
Spectra Manager installation disk 1 pc.
Instruction Manual 1 copy
Sample plate 1 pc.
Micro-sampling kit
consisting of
- Micro sampling knife S-type
- Micro sampling knife H-type
- Micro-needle for sample manipulation
- Tweezers for micro sampling
1 set
USB cable 2 pcs.
Cable between FT-IR and IR microscope 1 pc.
Connection plate between FT-IR and IR microscope 1 pc.
Connection pipe (for light path) between FT-IR and IR microscope 1 pc.
Spare fuses 2 pcs.
AC cable 1 set
Funnel 1 pc.
Lid for MCT dewar 1 pc.
Pipette 1 pc.
 
 

Australia

Learn more ›

New Zealand

Learn more ›

Australia Freephone

1800 00 84 53

sales.au@bio-strategy.com

 

New Zealand Freephone

0800 34 24 66

sales.nz@bio-strategy.com

 

Bio-Strategy PTY Limited

MELBOURNE (HQ)

8 – 10 Trade Park Drive

Tullamarine, VIC 3043

Australia

 

BRISBANE

2/7 Miller Street

Murarrie, QLD 4172

Australia

 

Bio-Strategy Limited

33 Westpoint Drive

Hobsonville

Auckland 0618

New Zealand

Advanced Analytical Solutions For Your Science

Electromag-01

Copyright © 2023 Bio-Strategy Limited. Terms & Conditions

Scroll To Top