Digital Polarimeter

System Description
The P-2000 is designed as a customizable polarimeter with various options for an array of applications and budgetary requirements. The system can also be field upgraded as application requirements change. Options for wavelength filters and source lamps provide a wide range of analytical wavelengths from UV-Vis to NIR.

Specifications
Principle | Automatic digital polarimeter with symmetric angular oscillation using the optical-null balance method |
Light Source | Tungsten-Halogen lamp (WI), Sodium lamp (Na), Mercury lamp (Hg) (Up to two light sourcess can be installed.) |
Modulator | Faraday cell |
Wavelength | 880, 633, 589, 578, 546, 436, 405, 365, 334, 325, 313, 302, 296, 280, 254 nm |
Aperture | 1.8, 3 and 8 mm diameters |
Angular Range | ±90° |
Response Speed | 6°/sec |
Measurement Accuracy | ±0.002° (up to 1°) |
Repeatability | ±0.2% (larger than 1°) 0.002° |
Resolution | 0.0001° |
Integration Time | 1 - 100 sec |
Detector | Photomultiplier tube (1P28-01) (R928 - option) |
Readout Modes | Optical rotation, optical specific rotation, concentration, sugar scale Z, Brix purity, optical purity |
Temperature Measurement Range | 0~40°C (minimum display temperature: 0.1°C) |
Dimensions | 653 (W) x 249 (D) x 364 (H) mm |
Weight | Approx. 30 kg |
Power Requirement | AC100~240V ±10%, 50 or 60 Hz, 80 - 300 W |
System Features
Advanced instrument control
High speed, precision and accuracy
The P-2000 offers a response speed as fast as six degrees per second to provide reproducible data for each measurement with a resolution of 0.0001°. A wide dynamic range of up to ±90° enables the system to measure chiral compounds over a broad range of concentrations. The sample chamber is equipped with an integrated temperature, the current temperature constantly updated on the instrument control screen.
Full line of accessories
In support of diverse applications, a full line of accessories including a variety of cylindrical cells: a demountable stainless steel cell, Peltier thermostatted cell holder, and monochromator options, all offered for functional expansions of the P-2000. Quick-connect fittings with flow control valves in the sample compartment provide simple and secure exchange of waterthermostatted cells for temperature control with water baths. A newly developed Peltier cell holder offers accurate temperature control with ±0.1° accuracy.
Reliability and instrument verification
An automated validation program is available for GLP/cGMP laboratories or those regulated by the FDA. The program can be used for automated periodic validation of light source energy, zero repeatability, and rotational accuracy/repeatability. Inspected filters, sample cells with certified optical path length, and NIST-traceable rotation plates are also available.
Ultimate flexibility
With its single optical platform, the P-2000 can be customized to provide the optimum performance for every application. By selecting the most suitable combination of optical elements, the instrument can be used in the ultra-violet, visible and/or NIR regions.
Details
A new generation of polarimeters offering simplicity, reliability and complete validation protocols
A validation program is included as standard for GLP/cGMP laboratories or those regulated by the FDA. The program can be used for periodic validation of light source energy, zero repeatability, and rotational accuracy/repeatability. Inspected filters, sample cells with a certified optical path length, and NIST-traceable quartz rotation plates are also available as options.
Full line of accessories
The P-2000 Digital Polarimeter provides a wide range of choices for the control system, light source, cell, cell holder and wavelengths ranging from the UV-Vis to the NIR. A system optimized for any requirement can be configured for the laboratory, including only those items required for the desired application(s).
Examples of versatile system configurations
A single wavelength system
- 546 nm with Hg or WI lamp
- 589 nm with Na or WI lamp
A dual wavelength system
- 589/546 nm with Na/Hg or WI lamp
5 wavelength system
- 589/578/546/436/365 nm with Na/Hg lamps
6 wavelength system
- 633/589/546/436/405/365 nm with WI lamp
7 wavelength system
- 633/589/578/546/436/405/365 nm with WI lamp
System expansion to UV range
- 334/313/302/296/280/254 nm with Hg lamp with the wavelength expansion option for the UV range
- 334/325 nm with WI lamp with the wavelength expansion option for the UV range
Multiple wavelength system for UV/Vis range
- 633/589/578/546/436/405/365/334/325 nm with WI lamp with the wavelength expansion option for the UV range
System expansion to NIR range
- 880 nm with WI lamp with the wavelength expansion option for the NIR range
Multiple wavelength system for NIR and Visible range
- 880/589 nm with WI lamp with the wavelength expansion option for the NIR range
- 880/589/546 nm with WI lamp with the wavelength expansion option for the NIR range
Applications
Single model strategy with ultimate flexibility
Rather than plural models, with no way to update functions, JASCO offers a single model to be configured in order to optimally meet your application requirements, yet easy to upgrade in the field, with a wide choice of available accessories.
A wide range of applications
- Foods
- Pharmaceuticals
- Sugars and Sweeteners
- Essential oils
- Flavors and Fragrances
- Chemicals
Australia
New Zealand
Australia Freephone
1800 00 84 53
sales.au@bio-strategy.com
New Zealand Freephone
0800 34 24 66
sales.nz@bio-strategy.com
Bio-Strategy PTY Limited
MELBOURNE (HQ)
8 – 10 Trade Park Drive
Tullamarine, VIC 3043
Australia
BRISBANE
2/7 Miller Street
Murarrie, QLD 4172
Australia
Bio-Strategy Limited
33 Westpoint Drive
Hobsonville
Auckland 0618
New Zealand
Advanced Analytical Solutions For Your Science

Copyright © 2023 Bio-Strategy Limited. Terms & Conditions